Primary Switch Mode Power Supplies

The CP range offers newest technology in a compact construction of power supplies. New product within assortment: CP-ASI power supplies for the use in AS-interfaces.

Characteristics of the CP-D range of power supplies
  • Output voltages 12 V, 24 V DC
  • Adjustable output voltages (devices > 10 W)
  • Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A
  • Power range 10 W, 30 W, 60 W, 100 W
  • Wide range input 100-240 V AC (90-264 V AC, 120-370 V DC)
  • High efficiency of up to 89 %
  • Low power dissipation and low heating
  • Free convection cooling (no forced cooling with ventilators)
  • Ambient temperature range during operation -25 ...+70 °C
  • Open-circuit, overload and short-circuit stable
  • Integrated input fuse
  • U/I characteristic (fold-forward behaviour at overload - no switch-off)
  • LEDs for status indication
  • Light-grey enclosure in RAL 7035

Characteristics of the CP-E range of power supplies
  • Output voltage 5 V, 12 V, 24 V, 48 V DC
  • Adjustable output voltages
  • Output current 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A / 5 A / 10 A / 20 A
  • Power range 18 W, 30 W, 60 W, 120 W, 240 W, 480 W
  • Wide range input or auto select input
  • High efficiency of up to 90 %
  • Low power dissipation and low heating
  • Free convection cooling (no forced cooling with ventilators)
  • Ambient temperature range during operation -25...+70 °C
  • Open-circuit, overload and short-circuit stable
  • Integrated input fuse
  • U/I characteristic curve on devices < 18 W (fold-forward behaviour at overload – no shutdown)
  • Redundancy units offering true redundancy
  • LED(s) for status indication
  • Signalling output/contact for output voltage OK
  • Transistor on 24 V devices > 18 W and < 120 W
  • Relay on 24 V devices ≥ 120 W


Characteristics of the CP-T range of power supplies
  • Output voltage 24 V or 48 V DC
  • Output voltage adjustable via front-face rotary potentiometer "OUTPUT Adjust"
  • Rated output current 5 A / 10 A/ 20 A / 40 A
  • Rated output power 120 W / 240 W / 480 W / 960 W
  • Supply range 3 x 400-500 V AC (3 x 340-575 V AC, 480-820 V DC)
  • Two-phase supply with a derating of the output to 75% possible/permitted
  • Typical efficiency of 89%
  • Low power dissipation and low heating
  • Free convection cooling (no forced cooling with ventilators)
  • Ambient temperature range during operation -25...+70 °C
  • Open-circuit, overload and short-circuit stable
  • Integrated input fuse
  • Redundancy unit CP-A RU offering true redundancy, available as accessory
  • Signalling contact "13-14" (Relay) for output voltage OK


Characteristics of the CP-S and CP-C range of power supplies
  • Output current 5 A, 10 A and 20 A
  • Integrated power reserve of up to 50 %
  • 5 A and 10 A devices with pluggable connecting terminals
  • Constant or adjustable output voltage (depending on type)
  • High efficiency of approx. 89 %
  • Low power dissipation and low heating
  • Open-circuit, overload and short-circuit stable
  • Integrated input fuse
  • LED for status indication
  • Redundancy unit CP-A RU offering true redundancy
  • Control module CP-A CM pluggable onto CP-A RU
  • CP-S range
  • 10 A and 20 A device with front-face selector switch to adjust rated input voltage range:
  • 110-120 V AC or 220-240 V AC
  • Output voltage fixed at 24 V DC
  • Parallel operation for redundancy

CP-C range of power supplies
  • Wide range input 110-240 V AC (85-264 V AC, 100-350 V DC)
  • Output voltage adjustable in a range of 22-28 V DC
  • Parallel operation for increased capacity and redundancy
  • Power factor correction (PFC) according to EN 61000-3-2
  • Function module CP-C MM pluggable onto the front side

Accessories:
Further acessories like buffer units, redundancy modules, control- and messaging modules as well as electronic protection devices you find in the "Accessories" tab on top of this page.


Characterstics of the CP-ASI range of power supplies
  • Rated output voltage 30.5 V DC
  • Rated output current 2.8 A
  • Infrared addressing mode 1)
  • High efficiency of up to 90.5 % 2)
  • Low power dissipation and low heating
  • Free convection cooling (no forced cooling with ventilators)
  • Ambient temperature range during operation -10…70 °C 3)
  • Open-circuit, overload and short-circuit stable
  • Integrated input fuse
  • Tool-free mounting on DIN rail as well as demounting
  • LEDs for the indication of operational states


1) except CP-ASI/4.0 DC/DC
2) Efficiency factor depending of device
3) Ambient temperature range CP-ASI/4.0 DC/DC -25...+70 °C